MFS-06e-Technical-data

Frequency range

0.0001 Hz .. 10 kHz

   

Frequency bands

0.0001 Hz 500 Hz (chopper on)
10 Hz 10 kHz (chopper off)

   

Sensor noise

1.1*10-2 nT/Hz @ 0.01 Hz
1.1*10
-4 nT/Hz @ 1 Hz
1.0*10
-6 nT/Hz @ 1000 Hz (chopper off)

   

Output sensitivity

0.2 V/(nT*Hz) f << 4 Hz
0.8 V/nT f >> 4 Hz
for exact values refer to individual calibration file

   

Output voltage range

+/- 10 V

   

Function

Induction coil with magnetic field feed back

   

Connector

ODU G32KON-T10QJ00-000 (coil socket)
ODU S22KON-T10MJG0-7000 (cable plug)

   

Calibration input sensitivity

4 nT / V

   

Feedback cut-off frequency

4 Hz

   

Supply voltage

+/- 12 V to +/- 15 V stabilized and filtered

   

Supply current

+/- 25 mA

   

Case

ruggedized, waterproof case

   

Weight

appr. 8.0 kg

   

External dimensions

length 1140 mm, diameter 75 mm

   

Operating temperature range

-25°C ..... + 70°C